Product - Cellulose
|
|
| |
|
|
| |
|
|
Product Description
BENO-THERM is derived from recycled wood fibre. Because of its natural
content, it is a non-polluting, and non-irritant material. Tests have proven
this product free of any gas emission whatsoever.
|
|
|
|
|
THERMAL PERFORMANCE
With an R value of 3.8/in. at a density of 1.6 lb/cu. ft. on open areas,
BENO-THERM provides the highest thermal resistance per unit of thickness
of all conventional insulating fibres on the market today.
|
|
|
| LOOSE FILL CELLULOSE |
| COVERAGE
CHART FOR VENTILATED ATTIC - PNEUMATIC APPLICATION |
| IMPERIAL SYSTEM |
METRIC SYSTEM |
"R" Factor |
As Applied (inch) |
Settled (inch) |
Lbs
/ Ft.² |
Ft.²
per bag
25 lbs |
Bags
per 1000Ft.² Minimum
|
"RSI" Factor |
As
Applied (mm) |
Settled (mm) |
Kg.
/ m² |
m²
per bag
11,3 Kg. |
Bags
per 100m² Minimum |
| R-10 |
(2.9) |
2.7 |
0.36 |
69.44 |
14.4 |
RSI-1.0 |
(44) |
40 |
1,00 |
11,04 |
9,1 |
| R-12 |
(3.5) |
3.2 |
0.43 |
58.14 |
17.1 |
RSI-2.0 |
(87) |
79 |
1,99 |
5,59 |
17,9 |
| R-20 |
(5.9) |
5.4 |
0.72 |
34.75 |
28.8 |
RSI-3.0 |
(131) |
119 |
3,04 |
3,71 |
27,0 |
| R-28 |
(8.3) |
7.5 |
1.00 |
25.00 |
40.0 |
RSI-4.0 |
(174) |
158 |
4,06 |
2,79 |
35,8 |
| R-30 |
(8.9) |
8.1 |
1.08 |
23.15 |
43.2 |
RSI-5.0 |
(218) |
198 |
5,07 |
2,23 |
44,9 |
| R-32 |
(9.5) |
8.6 |
1.14 |
21.92 |
45.9 |
RSI-6.0 |
(262) |
238 |
6,09 |
1,85 |
53,9 |
| R-35 |
(10.4) |
9.4 |
1.25 |
20.00 |
50.1 |
RSI-7.0 |
(305) |
277 |
7,09 |
1,59 |
62,8 |
| R-40 |
(11.9) |
10.8 |
1.44 |
17.36 |
57.6 |
RSI-8.0 |
(349) |
317 |
8,10 |
1,39 |
71,8 |
| R-50 |
(14.9) |
13.5 |
1.80 |
13.88 |
72.0 |
RSI-9.0 |
(393) |
357 |
9,12 |
1,24 |
80,9 |
| R-60 |
(17.8) |
16.2 |
2.16 |
11.58 |
86.4 |
RSI-10.8 |
(472) |
428 |
10,94 |
1,03 |
97,0 |
| *SETTLED
DENSITY: 1.6 lb. PER CUBIC FOOT / 25.6 KG. |
|
|
|
|
ACOUSTICAL PROPERTIES
BENO-THERM contains soundproofing properties and proven superior performance.
BENO-THERM is injected at 3.0 lb. density per cubic foot in party walls and
at 2.5 lb. density into existing ceilings/floors constructions directly through
2 in. holes pierced into the gypsum boards or, in the case of unfinished walls,
through a BENO-MAT membrane mesh stapled to the wall frame before installing
the closing wall panel.
|
See illustrations: walls and ceilings/floors
constructions (NBC 95 and IRC-766).
|
|
|
|
|
|
|
 |